Specialities & Therapies

Home Anaesthesia

G9L MONITOR

1. Universal common electrode is applicable, cost-saving and effective.

2. Real time monitor patient’s depth of anesthesia state in & after surger, reduce the surgical risk.

3. Suitable for adults, pediatics and neonates: widely used in OR/OT, ICU, CCU, NICU, etc..

Enquire Now

JUPITER 500

1. Rust free framework

2. Deep spacious drawer units

3. Dual cascaded rotameters for O2 and N2O as standard

4. Wide monitoring shelf at eye level

5. Convenient common gas outlet

6. Hook for breathing circuit

7. Open-Close circuit switch control

8. Convenient mounting of circle absorber

9. Twin Selectatec mountings for 2 Agent Specific Vaporisers

10. Pin Indexed yokes Two for O2 and One for N2O

11. Anaesthetic gas scavenging port

12. Large, roller bearing, anti-static castors with front wheel brakes

13. Electrical outlets for connecting monitors

14. Central pipeline connections with gas specific NIST connectors

Enquire Now

JUPITER 200

1. Deep and spacious drawer units & convenient footrest

2. Wide monitoring shelf at eye level with securing provision

3. Convenient swivel common gas outlet

4. Hook for breathing circuit

5. Wipe-clean stainless steel table top

6. Auxiliary high pressure Oxygen outlets.

7. Extended platform at rear for two 10 Ltr water capacity cylinders* (optional)

8. Open / Close circuit switch control

9. Pin indexed yokes for O2 & N2O

10. Convenient mounting of circle absorber

11. Choice of backbar for SELECTATEC or Cagemount vaporisers

12. Active / passive anaesthetic gas scavenging interface and suction (optional)

13. Integrated rear bumper/ side handle for improved maneuverability

14. Large, roller bearing, anti-static castors with front wheel brakes

Enquire Now

CWH – 1020

Main Features:

1. Applied for adult and pediatric

2. Microprocessor controlled ,integrated anesthetic ventilation system

3. 7 inch TFT display screen

4. Safety Good air tightness, high reliability

Main specifications:

1. Electronically controlled, pneumatic driven

2. Patient spectrum: pediatric to bariatric

3. Ventilation mode: VCV, SIMV, PCV, MANUAL(BAG)

4. Tidal volume: Adjustment range 20 ~1500ml

5. I:E ratio: 4:1~1:8

Frequency:

1. Adjustment range: 1~100bpm

2. Under IPPV and Manual mode: 4~65bpm

3. Under SIMV: 1~ 40bpm

Monitoring:

1. VT, MV, BPM, Paw, FiO2, PEEP, Respiratory Frequency, I:E ratio, Ppeak

Waveform:

1. Pressure- time, Flow- time, F-V loop, P-V loop

2. Power: AC 220V±10%, 50HZ±2%, built-in battery > 2hrs(rechargeable) 12V

3. Inspiratory time (TI) (at SIMV) — Adjustment range: 0.2 s ~ 6.0 s (the limit of I:E ratio ≤ 4)

4. Pressure trigger: -20 cmH2O ~ +20 cmH2O

5. Power: AC 220V±10%, 50HZ±2%, built-in battery > 2hrs(rechargeable) 12V

6. Inspiratory time (TI) (at SIMV) — Adjustment range: 0.2 s ~ 6.0 s (the limit of I:E ratio ≤ 4)

7. Pressure trigger: -20 cmH2O ~ +20 cmH2O

Pressure limit:

1. Patient airway pressure range: -2kPa ~ 10kPa

2. Airway pressure monitoring range: 0 ~10kPa

3. PEEP: 3 ~ 20cmH2O

4. Safety valve pressure limit: ≤ 6kPa

6. Alarm: High(low) pressure alarm, High(Low) MV alarm,AC power lost alarm.

Enquire Now

CWM 302

2 vaporizers, 5 tubes o2, n2o and air flowmeter, ventilator, oxygen flush system, 8. 4inchscreen,compact breathing loop System,knob operation, build-in battery and accessories.

Enquire Now